Air-Cooled Water Chillers

Product Overview

TIC-A Air-Cooled Water Chillers include four main components, such as compressor, condenser, thermostatic expansion valve and evaporator. The system adopts a single closed-loop design for refrigeration system. Refrigerant is alternatively changed from gaseous to liquid state to absorb or release heat thus a cooling effect is achieved. When the machine is started, compressor starts working. Refrigerant is compressed into high pressure and high temperature gas in the process from A to B. In the process From B to C and D, this high pressure and high temperature gas is cooled when it is passing through the condenser and changed into liquid. Heat is taken away by the cooling air. In the process from D to Ei the pressure of liquid refrigerant is reduced by expansion valve and a part of the refrigerant is changed from liquid to gaseous state. In the process from E to A, refrigerant absorbs the heat of process water in the evaporator and returns back to the compressor. This heat exchange process repeats until process water is cooled down to required temperature. 1.Stainless iron water tank for storage of circulation water. 2.Heavy duty 3-phase pump ensures no blockages and high torque. 3.High/low system pressure gauges. 4.Main power switch. 5.Pump pressure gauge. 6.Scroll/ piston type compressor(s) for super high efficiency and low noise 7.Refrigerant tank is fixed to make full use of the condenser cooling fin.

2025nd Year

Contact Person

Ruida Industrial Park,

Product Description

TIC-A Air-Cooled Water Chillers include four main components, such as compressor, condenser, thermostatic expansion valve and evaporator. The system adopts a single closed-loop design for refrigeration system. Refrigerant is alternatively changed from gaseous to liquid state to absorb or release heat thus a cooling effect is achieved. When the machine is started, compressor starts working. Refrigerant is compressed into high pressure and high temperature gas in the process from A to B. In the process From B to C and D, this high pressure and high temperature gas is cooled when it is passing through the condenser and changed into liquid. Heat is taken away by the cooling air. In the process from D to Ei the pressure of liquid refrigerant is reduced by expansion valve and a part of the refrigerant is changed from liquid to gaseous state. In the process from E to A, refrigerant absorbs the heat of process water in the evaporator and returns back to the compressor. This heat exchange process repeats until process water is cooled down to required temperature. 1.Stainless iron water tank for storage of circulation water. 2.Heavy duty 3-phase pump ensures no blockages and high torque. 3.High/low system pressure gauges. 4.Main power switch. 5.Pump pressure gauge. 6.Scroll/ piston type compressor(s) for super high efficiency and low noise 7.Refrigerant tank is fixed to make full use of the condenser cooling fin.