Product Overview
Technical Features of Combo UPS: MAINS LOW CUTT OFF is 185V in Narrow Range & 95V in Wide Range MAINS HIGH CUTT OFF is 260 V inNarrow Range & 295V in Wide Range CHARGING IN SYSTEM OFF is 150 V - 295 V in Narrow Range & 150 V - 295 V in wide range. CHARGING IN SYSTEM ON is 185 V - 250 V in Narrow Range & 150 V - 295 V in Wide Range. OVERLOAD RESET is MANUAL in narrow range & AUTOMATIC in Wide Range. CHANGEOVER TIME is 3m Sec OUTPUT VOLTAGE is 220 +/- 8% V, 50.0 Hz AC OVERLOAD CAPACITY : 110% Cont., 300% for 30 mS. BATTERY CHARGING RATE : Const. Curr. 7% of Batt. Capacity AUDIO ALARM : Buzzer for Overload & Low Battery EFFICIENCY : 85% Typical Specifications are subject to change without any prior notice, due to our continuous endeavour to improve the product.
Technical Features of Combo UPS: MAINS LOW CUTT OFF is 185V in Narrow Range & 95V in Wide Range MAINS HIGH CUTT OFF is 260 V inNarrow Range & 295V in Wide Range CHARGING IN SYSTEM OFF is 150 V - 295 V in Narrow Range & 150 V - 295 V in wide range. CHARGING IN SYSTEM ON is 185 V - 250 V in Narrow Range & 150 V - 295 V in Wide Range. OVERLOAD RESET is MANUAL in narrow range & AUTOMATIC in Wide Range. CHANGEOVER TIME is 3m Sec OUTPUT VOLTAGE is 220 +/- 8% V, 50.0 Hz AC OVERLOAD CAPACITY : 110% Cont., 300% for 30 mS. BATTERY CHARGING RATE : Const. Curr. 7% of Batt. Capacity AUDIO ALARM : Buzzer for Overload & Low Battery EFFICIENCY : 85% Typical Specifications are subject to change without any prior notice, due to our continuous endeavour to improve the product.