Product Overview
Safetrack insulated conductors are designed in accordance to international regulations for multitude of power supply applications. These conductors are compact, insulated, easy to install, in horizontal or vertical configuration. They require much less space compared to conventional bare conductor systems. The conductor bars are 4 meters long to be supported at every 1 metre, effecting considerable savings in installation. Conductors are easily assembled at site with the use of a jointing tool. All bars are supplied with connecting pins. Design allows uni/multi pole mounting arrangement. Conductors can be mounted side by side min. centre distance 30 mm. Factor made curved conductors available. Galvanised iron conductor - rated 100A / 125A Copper conductor - rated 250A/315A S.S. Conductor - rated 40A MOUNTING Insulated hanger clamps support conductor. Standard mounting brackets available or designed for specific requirement. The conductor can be mounted horizontally or vertically. No minimum clearance required with other structures. FEED TERMINALS The power feed point can be at the ends or anywhere along the run. One or more power feed point positions possible to reduce voltage drop. Feed terminal clamps should preferably be installed at rail joints. END CAPS The open ends / end feeds of condutors are covered by end caps. COLLECTOR
Contact Person
D-7, GHATKAPOR INDUSTRIAL ESTATE, OFF. L.B.S. MARG, Ghatkopar (W),
Safetrack insulated conductors are designed in accordance to international regulations for multitude of power supply applications. These conductors are compact, insulated, easy to install, in horizontal or vertical configuration. They require much less space compared to conventional bare conductor systems. The conductor bars are 4 meters long to be supported at every 1 metre, effecting considerable savings in installation. Conductors are easily assembled at site with the use of a jointing tool. All bars are supplied with connecting pins. Design allows uni/multi pole mounting arrangement. Conductors can be mounted side by side min. centre distance 30 mm. Factor made curved conductors available. Galvanised iron conductor - rated 100A / 125A Copper conductor - rated 250A/315A S.S. Conductor - rated 40A MOUNTING Insulated hanger clamps support conductor. Standard mounting brackets available or designed for specific requirement. The conductor can be mounted horizontally or vertically. No minimum clearance required with other structures. FEED TERMINALS The power feed point can be at the ends or anywhere along the run. One or more power feed point positions possible to reduce voltage drop. Feed terminal clamps should preferably be installed at rail joints. END CAPS The open ends / end feeds of condutors are covered by end caps. COLLECTOR